NI cDAQ-918x/919x User Manual
Reset Button
The cDAQ chassis is equipped with a reset button.
Pressing the reset button results in the following chassis responses:
When pressed for less than five seconds, the chassis reboots with the current configuration.
When pressed for five seconds or longer, the STATUS LED lights. When released, the
chassis reboots into factory default mode, which returns the chassis user configuration to
the factory-set defaults listed in Table 1-6.
Power Connector
Refer to the specifications document for your cDAQ chassis for information about the power
connector on the cDAQ chassis.
PFI BNC Connectors
(NI cDAQ-9188) Refer to the PFI section of Chapter 4, Digital Input/Output and PFI, for
information about the BNC connectors for PFI 0 and PFI 1.
Antenna
(NI cDAQ-9191) Refer to the NI cDAQ-9191 Specifications for information about the antenna
on the NI cDAQ-9191 chassis.
Table 1-6. NI cDAQ Chassis Default Settings
Attribute Value
Hostname cDAQ91xx-<serial number>
IP DHCP or Link Local
Comment Empty
NI Auth User name = admin Password = no password required